Fuses
600V 6A RK1 TD FUSE
Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Branch circuit protection; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Motors; All general-purpose circuits; Control panels; Recommended for Arc Flash energy reduction
J TD FUSE 600V 45A AJT
Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Motor circuits; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 No. 248.8; DC tested to UL standard 248; Feeders; Control panels; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Non-indicating or solid state SmartSpot visual blown fuse indicator; Mains; Most current-limiting UL class fuse; Circuit breaker back-up; UL listed; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Load centers; Recommended for Arc Flash energy reduction; High-grade silica filler ensures fast arc quenching; Branch circuits; Transformers; IEC 60269-2-1; Time-delay for motor starting and transformer inrush
CC TD FUSE 600V 7A ATDR
Metal-embossed date and catalog number for traceability and lasting identification; Branch circuit protection; Lighting, heating & general loads; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting inrush currents without nuisance opening; Contactors; DC listed to UL standard 248; Highly current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.4; Small motors; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; UL listed to standard 248-4 File E2137; High-visibility orange label ensures instant brand recognition, simplifies replacement
600V 8A CC TD FUSE(ATDR8)
Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and optimum current-limitation; Metal-embossed date and catalog number for traceability and lasting identification; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Lighting, heating & general loads; DC listed to UL standard 248; Contactors; CSA certified to standard C22.2 No. 248.4; Time-delay for motor starting inrush currents without nuisance opening; High-visibility orange label ensures instant brand recognition, simplifies replacement; Highly current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-4 File E2137; Small motors; Branch circuit protection
600V 15A CC FUSE
Control circuits; Branch circuit protection; Lighting; UL Listed to Standard 248-4 File E2137; CSA Certified to Standard C22.2 No. 248.4; Rejection-style design prevents replacement errors when used with recommended fuse blocks; Versatile design for individual component and branch circuit protection; General loads; DC listed to UL Standard 248
500V 20A TD MIDGET FUSE
1 1/2” x 13/32” (10 mm x 38 mm) dimensions; UL listed to standard 248-14 File E33925; Can be used with UltraSafe™ Fuse holders; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; Numerous ratings for a wide variety of applications up to 500VAC; Supplemental protection of lighting, solenoid, motor and transformer circuits; CSA Certified to Standard C22.2 No. 248.14
CC TD FUSE 600V 1/4A ATQR
High-grade silica filler ensures fast arc quenching and high current limitation; Highly current-limiting for low peak let-thru current; Control transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for control transformer inrush loads without nuisance opening; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; Solenoids; High visibility orange label ensures instant brand recognition, and simplifies replacement; CSA certified to standard C22.2 No. 248.4; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-4 File E2137; Inductive loads; Lighting, heating & general-purpose loads
CC TD FUSE 600V 8/10A ATQR
Solenoids; Lighting, heating & general-purpose loads; Control transformers; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; Highly current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.4; UL listed to standard 248-4 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for control transformer inrush loads without nuisance opening; High visibility orange label ensures instant brand recognition, and simplifies replacement; DC listed to UL standard 248; Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation
CC TD FUSE 600V 9A ATQR
Solenoids; CSA certified to standard C22.2 No. 248.4; Time-delay for control transformer inrush loads without nuisance opening; Control transformers; High-grade silica filler ensures fast arc quenching and high current limitation; Inductive loads; Lighting, heating & general-purpose loads; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-4 File E2137; Highly current-limiting for low peak let-thru current; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; High visibility orange label ensures instant brand recognition, and simplifies replacement
Switchfus 200A J R 3+0 pos
Power taps; All UL Fusible Disconnect Switches meet UL & CSA requirements; Interlocked fuse doors; Fuse monitoring; Multiple Configurations; IEC 60947-3; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A); Double break, isolating live and load side of fuse; Adjustable shaft depth